Brand Name :REXON
Model Number :Series ZA-DPM
Certification :CE, ISO, SGS, CCC
Place of Origin :China
Function :Dew Point Measuring
Working Flow :2~3SCFH(1SCFH≈500ml/min)
Temperature :-20℃~60℃
Humidity :0~100%RH
Display :LCD Touch Screen
Output :RS232 or 485
Power Supply :8,000mAH Lithium Battery
Dimension :300×280×150mm
Guarantee Period :2 Years
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Description

ZA-DPM Portable Dew Point Meter takes a high-performance micro-processor as the core, 480×272 TFT16 color touch display as the human-computer interaction platform and the imported sensor with reliable performance as the sensitive element, and integrates real-time measurement, curve display, power supply management, time system, file system, data inquiry, intelligent automatic calibration and many other functions. The integration of advanced sensor technology and information technology, user-friendly operation and massive function allow you to experience its superiority and perfect design. ZA-DPM Portable Dew Point Meter, used to measure the moisture content in gas, has an automatic conversion function of dew-point under standard temperature and pressure.

Features

Automatic calibration of dew-point upon equipment on

Display of real-time curve

Color touch display

Storage of measurement data

Automatic conversion of dew-point under standard temperature and pressure (ppms)

Display of system time

Display of smart electric quantity

File storage system

Optional infrared printer

Technical Parameters

DMT242 sensor based
Measuring range Dew-point temperature: -80℃~+20℃
Uncertainty ±2℃
Response time T63[T90] at the gas temperature of 20℃:
Dew-point temperature: -60→-20℃ 5s[10s]
Dew-point temperature: -20→-60℃ 45s[10min]

DMT143 sensor based
Measuring range Dew-point temperature: -60℃~+60℃
Uncertainty ±2℃
Response time T63[T90] at the gas temperature of 20℃:
Dew-point temperature: -60→-20℃ 5s[150s]
Dew-point temperature: -20→-60℃ 45s[10min]

DMT152 sensor based
Measuring range Dew-point temperature: -80℃~-30℃
Uncertainty ±2℃
Response time T63[T90] at the gas temperature of 20℃:
Dew-point temperature: -80→-30℃ 10s[20s]
Dew-point temperature: -30→-80℃ 2min[30min]


Complete machine parameter
Working flow: 2~3SCFH(1SCFH≈500ml/min)
Battery Lithium battery 8,000mAH
Hours of use >10 hours
Digital output RS232 or 485
Environmental condition:

Temperature: -20℃~60℃

Humidity: 0~100%RH
External dimension 300mm×280mm×150mm
Weight about 5kg